980 resultados para blood sampling


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Anaemia is common in critically ill patients, and has a significant negative impact on patients' recovery. Blood conservation strategies have been developed to reduce the incidence of iatrogenic anaemic caused by sampling for diagnostic testing. Objectives Describe practice and local guidelines in adult, paediatric and neonatal Australian intensive care units (ICUs) regarding blood sampling and conservation strategies. Methods Cross-sectional descriptive study, conducted July 2013 over one week in single adult, paediatric and neonatal ICUs in Brisbane. Data were collected on diagnostic blood samples obtained during the study period, including demographic and acuity data of patients. Institutional blood conservation practice and guidelines were compared against seven evidence-based recommendations. Results A total of 940 blood sampling episodes from 96 patients were examined across three sites. Arterial blood gas was the predominant reason for blood sampling in each unit, accounting for 82% of adult, 80% of paediatric and 47% of neonatal samples taken (p <. 0.001). Adult patients had significantly more median [IQR] samples per day in comparison to paediatrics and neonates (adults 5.0 [2.4]; paediatrics 2.3 [2.9]; neonatal 0.7 [2.7]), which significantly increased median [IQR] blood sampling costs per day (adults AUD$101.11 [54.71]; paediatrics AUD$41.55 [56.74]; neonatal AUD$8.13 [14.95]; p <. 0.001). The total volume of samples per day (median [IQR]) was also highest in adults (adults 22.3. mL [16.8]; paediatrics 5.0. mL [1.0]; neonates 0.16. mL [0.4]). There was little information about blood conservation strategies in the local clinical practice guidelines, with the adult and neonatal sites including none of the seven recommendations. Conclusions There was significant variation in blood sampling practice and conservation strategies between critical care settings. This has implications not only for anaemia but also infection control and healthcare costs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To explore children's views on microneedle use for this population, particularly as an alternative approach to blood sampling, in monitoring applications, and so, examine the acceptability of this approach to children.

Methods: Focus groups were conducted with children (aged 10-14 years) in a range of schools across Northern Ireland. Convenience sampling was employed, i.e. children involved in a university-directed community-outreach project (Pharmacists in Schools) were recruited.

Key findings: A total of 86 children participated in 13 focus groups across seven schools in Northern Ireland. A widespread disapproval for blood sampling was evident, with pain, blood and traditional needle visualisation particularly unpopular aspects. In general, microneedles had greater visual acceptability and caused less fear. A patch-based design enabled minimal patient awareness of the monitoring procedure, with personalised designs, e.g. cartoon themes, favoured. Children's concerns included possible allergy and potential inaccuracies with this novel approach; however, many had confidence in the judgement of healthcare professionals if deeming this technique appropriate. They considered paediatric patient education critical for acceptance of this new approach and called for an alternative name, without any reference to 'needles'.

Conclusions: The findings presented here support the development of blood-free, minimally invasive techniques and provide an initial indication of microneedle acceptability in children, particularly for monitoring purposes. A proactive response to these unique insights should enable microneedle array design to better meet the needs of this end-user group. Further work in this area is recommended to ascertain the perspectives of a purposive sample of children with chronic conditions who require regular monitoring. © 2013 Royal Pharmaceutical Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Microneedle (MN) arrays could offer a pain-free, minimally invasive approach to monitoring. This is envisaged to be particularly beneficial for younger patients, but parents' views to date are unknown. The aim of this study was to explore parental perceptions of MN-mediated ISF monitoring, as an alternative to the use of conventional blood sampling, and to understand the important factors for technique approval.

METHODS: Semi-structured interviews were conducted with parents with recent experience of a premature birth. Recruitment was through the Northern Ireland premature infant charity, Tinylife. Interviews progressed until data saturation was reached and thematic analysis employed.

KEY FINDINGS: The study included 16 parents. Parental support for MN-mediated monitoring was evident, alongside the unpopularity of traditional blood sampling in neonates. Factors facilitating MN approval included the opportunity for pain reduction, the simplicity of the procedure, the potential for increased parental involvement and the more favourable appearance, owing to the minute size of MNs and similarities with a sticking plaster. Confirmation of correct application, a pain-free patch removal and endorsement from trusted healthcare professionals were important.

CONCLUSION: These findings will inform researchers in the field of MN development and enlighten practitioners regarding parental distress resulting from conventional blood sampling. Further work is necessary to understand MN acceptability among practitioners. This work should assist in the development of an acceptable MN device and facilitate the reduction of parental distress.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction/objectives: Multipatient use of a single-patient CBSD occurred inan outpatient clinic during 4 to 16 months before itsnotification. We looked for transmission of blood-bornepathogens among exposed patients.Methods: Exposed patients underwent serology testing for HBV,HCV and HIV. Patients with isolated anti-HBc receivedone dose of hepatitis B vaccine to look for a memoryimmune response. Possible transmissions were investigatedby mapping visits and sequencing of the viral genomeif needed.Results: Of 280 exposed patients, 9 had died without suspicionof blood-borne infection, 3 could not be tested, and 5declined investigations. Among the 263 (93%) testedpatients, 218 (83%) had negative results. We confirmeda known history of HCV infection in 6 patients (1 coinfectedby HIV), and also identified resolved HBVinfection in 37 patients, of whom 18 were alreadyknown. 2 patients were found to have a previouslyunknown HCV infection. According to the time elapsedfrom the closest previous visit of a HCV-infected potentialsource patient, we could rule out nosocomial transmissionin one case (14 weeks) but not in the other (1day). In the latter, however, transmission was deemedvery unlikely by 2 reference centers based on thesequences of the E1 and HVR1 regions of the virus.Conclusion: We did not identify any transmission of blood-bornepathogens in 263 patients exposed to a single-patientCBSD, despite the presence of potential source cases.Change of needle and disinfection of the device betweenpatients may have contributed to this outcome.Although we cannot exclude transmission of HBV, previousacquisition in endemic countries is a more likelyexplanation in this multi-national population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chronic catheterization is illustrated using vascular-access-port model SLA where the port is surgically placed subcutaneously on the back of the rat. The catheter is tunnelled to the neck and inserted into the jugular vein . Within 24 h rats showed normal blood pressure and blood samples were collected at intervals with minimal stress to the animals . A comparison of the plasma catecholamine of blood collected from vascular-access-ports with that obtained from decapitation indicates that there was minimal stress to the rats when blood was drawn through the vascular-access-port.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Therapeutic drug monitoring of patients receiving once daily aminoglycoside therapy can be performed using pharmacokinetic (PK) formulas or Bayesian calculations. While these methods produced comparable results, their performance has never been checked against full PK profiles. We performed a PK study in order to compare both methods and to determine the best time-points to estimate AUC0-24 and peak concentrations (C max). METHODS We obtained full PK profiles in 14 patients receiving a once daily aminoglycoside therapy. PK parameters were calculated with PKSolver using non-compartmental methods. The calculated PK parameters were then compared with parameters estimated using an algorithm based on two serum concentrations (two-point method) or the software TCIWorks (Bayesian method). RESULTS For tobramycin and gentamicin, AUC0-24 and C max could be reliably estimated using a first serum concentration obtained at 1 h and a second one between 8 and 10 h after start of the infusion. The two-point and the Bayesian method produced similar results. For amikacin, AUC0-24 could reliably be estimated by both methods. C max was underestimated by 10-20% by the two-point method and by up to 30% with a large variation by the Bayesian method. CONCLUSIONS The ideal time-points for therapeutic drug monitoring of once daily administered aminoglycosides are 1 h after start of a 30-min infusion for the first time-point and 8-10 h after start of the infusion for the second time-point. Duration of the infusion and accurate registration of the time-points of blood drawing are essential for obtaining precise predictions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Blood sampling is an essential technique in many herpetological studies. This paper describes a quick and humane technique to collect blood samples from three species of Australian chelid turtles ( Order Pleurodira): Chelodina expansa, Elseya latisternum, and Emydura macquarii signata.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Optimal design methods have been proposed to determine the best sampling times when sparse blood sampling is required in clinical pharmacokinetic studies. However, the optimal blood sampling time points may not be feasible in clinical practice. Sampling windows, a time interval for blood sample collection, have been proposed to provide flexibility in blood sampling times while preserving efficient parameter estimation. Because of the complexity of the population pharmacokinetic models, which are generally nonlinear mixed effects models, there is no analytical solution available to determine sampling windows. We propose a method for determination of sampling windows based on MCMC sampling techniques. The proposed method attains a stationary distribution rapidly and provides time-sensitive windows around the optimal design points. The proposed method is applicable to determine sampling windows for any nonlinear mixed effects model although our work focuses on an application to population pharmacokinetic models.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Malaria rapid diagnostic tests (RDTs) are increasingly used by remote health personnel with minimal training in laboratory techniques. RDTs must, therefore, be as simple, safe and reliable as possible. Transfer of blood from the patient to the RDT is critical to safety and accuracy, and poses a significant challenge to many users. Blood transfer devices were evaluated for accuracy and precision of volume transferred, safety and ease of use, to identify the most appropriate devices for use with RDTs in routine clinical care. Methods: Five devices, a loop, straw-pipette, calibrated pipette, glass capillary tube, and a new inverted cup device, were evaluated in Nigeria, the Philippines and Uganda. The 227 participating health workers used each device to transfer blood from a simulated finger-prick site to filter paper. For each transfer, the number of attempts required to collect and deposit blood and any spilling of blood during transfer were recorded. Perceptions of ease of use and safety of each device were recorded for each participant. Blood volume transferred was calculated from the area of blood spots deposited on filter paper. Results: The overall mean volumes transferred by devices differed significantly from the target volume of 5 microliters (p < 0.001). The inverted cup (4.6 microliters) most closely approximated the target volume. The glass capillary was excluded from volume analysis as the estimation method used is not compatible with this device. The calibrated pipette accounted for the largest proportion of blood exposures (23/225, 10%); exposures ranged from 2% to 6% for the other four devices. The inverted cup was considered easiest to use in blood collection (206/ 226, 91%); the straw-pipette and calibrated pipette were rated lowest (143/225 [64%] and 135/225 [60%] respectively). Overall, the inverted cup was the most preferred device (72%, 163/227), followed by the loop (61%, 138/227). Conclusions: The performance of blood transfer devices varied in this evaluation of accuracy, blood safety, ease of use, and user preference. The inverted cup design achieved the highest overall performance, while the loop also performed well. These findings have relevance for any point-of-care diagnostics that require blood sampling.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Mitochondria produce cellular energy but also free-radicals, which damage cells despite an array of endogenous anti-oxidants. In Northern Europe, the mitochondrial haplogroup J has been related to longevity in nonagenarians and centenarians but also with age-related disease. Hypertension is an important contributor to atherosclerotic-related diseases and its pathogenesis is associated with increased oxidative stress. In this study, we questioned whether J haplogroup octo/nonagenarians from the Belfast Elderly Longitudinal Free-living Elderly STudy (BELFAST) study showed evidence of protective blood pressure or anti-oxidant profile which might explain their longevity advantage. Briefly, in a cross-sectional study, community-living, mentally alert (Folstein >25/30), octo/nonagenarian subjects, recruited for good health, were enlisted and consented as part of the BELFAST study, for blood pressure, anthropometric measurements and blood sampling. DNA typing for mitochondrial haplotypes was carried out with measurements for enzymatic and non-enzymatic antioxidants. J haplogroup carriers showed lower systolic blood pressure and glutathione peroxidase activity (Gpx) with higher folate measurements. There was no change in urate, bilirubin, albumin or nutrition-related antioxidants-selenium or vitamins A, C and a and ß carotene. BELFAST study mtDNA J haplogroup octo/nonagenarians showed lower blood pressure and reduced glutathione peroxidase activity and higher folate, but no change for other antioxidants. These findings are of interest in view of mtDNA J haplogroup's association with increased age in some previous studies.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Epidemiological studies show that elevated plasma levels of advanced glycation end products (AGEs) are associated with diabetes, kidney disease, and heart disease. Thus AGEs have been used as disease progression markers. However, the effects of variations in biological sample processing procedures on the level of AGEs in plasma/serum samples have not been investigated. The objective of this investigation was to assess the effect of variations in blood sample collection on measured Ne_(carboxy-methyl)lysine (CML), the best characterised AGE, and its homolog, Ne_(carboxyethyl)lysine (CEL). The investigation examined the effect on CML and CEL of different blood collection tubes, inclusion of a stabilising cocktail, effect of freeze thaw cycles, different storage times and temperatures, and effects of delaying centrifugation on a pooled sample from healthy volunteers. CML and CEL were measured in extracted samples by ultra_performance liquid chromatography-tandem mass spectrometry. Median CML and CEL ranged from 0.132 to 0.140 mM/M lys and from 0.053 to 0.060 mM/M lys, respectively. No significant difference was shown CML or CEL in plasma/serum samples. Therefore samples collected as part of epidemiological studies that do not undergo specific sample treatment at collection are suitable for measuring CML and CEL.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Analysis of the peripheral blood cells of Murray cod Maccullochella peelii peelii identified seven distinct subpopulations including a novel basophilic cell. Haematological reference ranges were established to facilitate future diagnostic blood sampling of this fish.